Which voltage window does the robot accept?
Read the series count and nominal voltage from the original pack documentation. Compare its limits with the controller’s minimum and maximum input voltage, then check the dock profile against the proposed pack. These two New Journey models illustrate the screening decision for different original packs.
| Original pack to investigate | New Journey candidate | Published voltage data to check |
|---|---|---|
| 16S, 51.2V nominal | 30Ah AMR battery · 16S1P, 51.2V, LiFePO4 | 40–58.4V operating range. Obtain the required charge profile separately before approving the dock. |
| 15S, 48.0V nominal | 60Ah AMR battery · 15S, 48.0V, LiFePO4 | 54.75V upper charge reference. Confirm the final charge profile for the project. |
The capacities in the table belong to these particular models. A buyer seeking more capacity for a 16S robot should specify that capacity within the approved voltage window. The 15S example cannot qualify on capacity alone, and a capacity increase by itself gives no basis for keeping the original dock.
Will the controller release the robot to work?
Trace one docking cycle with the controls engineer. Which signal authorizes charging once the contacts mate? Which pack status does the vehicle require before it can drive away? When a battery fault clears, does the controller expect a reset acknowledgement, a fresh drive-ready signal or another sequence defined by the vehicle? Record the expected exchange and who sends each signal. A CAN or RS485 label identifies an interface but leaves the messages and timing open.
Use the agreed sequence when accepting the sample. Power up the robot, send it to the dock, confirm that charging starts, then release it back to work. Record the expected fault-recovery response as a separate acceptance item. For sizing capacity against the work cycle and the time available for charging, see the AGV and AMR battery selection guide.
Can a technician remove the installed sample?
Mark the bay opening and the usable space behind it on the same drawing. Show the removal direction, cable exit, mating connector and the clearance a technician needs to release the latch. For chassis-mounted charging contacts, locate them from the pack mounting points. This lets the supplier check alignment with the pack secured and access when it comes out.
What should the replacement quote cover?
Send the robot model, original pack part number, required capacity, dock charge profile and interface drawing. Mark the parts that must stay on the vehicle. Ask the supplier to identify the proposed pack, any harness or protocol changes, and the checks that still require a sample on your robot. Other configurations are available for review in the robot battery range.
NEW JOURNEY